900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay
900ELR-2-230V-CE
900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay
- Backlit Liquid Crystal Display
Features
• 1Ø - 2 Wire, 3Ø - 3 Wire, 3Ø - 4 Wire Input
• Current leakage / ground fault monitoring, 10mA - 30A
• True RMS measurement
• CBCT connection monitoring
• Power ON delay, Trip time delay and Recovery time delay
• Adjustable switching hysteresis
• Two separate alarm relays with NO or NC operation selectable
• Test and Reset buttons via front / remote
• LCD with backlight
• DIN Rail Mount
• Size: 35mm (Width)

DATA Sheet Link
< Product photo may vary depending on part number selection.
Analog / Digital Protection Relays
Protection
Altech is pleased to offer a variety of protection relays covering:
Phase Monitoring
Voltage Monitoring
Current Monitoring
Frequency Monitoring
Current Leakage / Ground Fault Monitoring Protection relays help to maintain systems and ensure that proper action is taken when a fault is detected. Such functions help to preserve productivity and operational effectiveness of integral components.
- Process Controllers - Supply Voltage
- 230V AC
- Process Contollers - Input Voltage
- 110/230 V AC (45-65Hz)
- Process Controllers - Input Measurement
- Current Leakage (Via CBCT)
- Process Controllers - Trip Setting
- Leakage Current: 10mA-30A / Pre-Alarm: 50-100% of Leakage Current Setting
- Process Controllers - Main Output
- SPDT -2 C/O - NO: 5A, 250 V AC and NC:3A, 250 V AC
- Process Controllers - Trip Time Settings
- Power ON Delay: 0.5-99.9 sec / Trip Time Delay: 0-99.9 sec / Recovery Time Delay: 0-99.9 sec / Response Time: greater than 30ms (if trip current 5x set value) / greater than 50ms (if trip current 1x set value)
- Process Controllers - Hysteresis
- 5-40% of set value
- Process Controllers - Reset
- Auto/Manual (Selectable)
- Process Controllers - Power Consumption
- 3VA max
- Process Controllers - Operating Temperature
- 0 to 50°C (32 to 122°F)
- Process Controllers - Storage Temperature
- -20 to 75°C (-4 to 167°F)
- Process Controllers - Humidity (Non-Condensing)
- 95% Relative Humidity
- Process Controllers - Weight
- 217 grams(.48 lbs)
- Process Controllers - Display Type
- Liquid Crystal Display with backlight
- Process Controllers - Digits
- 1 row of 3 digits
- Process Controllers - Resolution
- Current: 0.1mA / 1mA / 0.01A, 0.1A
- Process Controllers - Current Rating
- Measuring Range (RMS Value) 10mA - 30A, 45-65Hz
- Process Controllers - Latching
- Selectable
- Process Controllers - Electrical Connection
- 1Ø-2 wire, 3Ø-3 wire, 3Ø- 4 wire
- Process Controllers - Current
- +/-5% of setting
- Process Controllers - Power Delay
- +/-5% of setting + 100ms
- Process Controllers - Protection Level
- IP50 (for faceplate), IP30 (for housing), IP20 (for terminals)