    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers
    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers
    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers
    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers
    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers
    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay|Process Controllers

    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay

    900ELR-2-230V-CE

    900ELR-2-230V-CE - Digital 1Ø/3Ø Current Leakage Relay
    - Backlit Liquid Crystal Display


    Features

    •  1Ø - 2 Wire, 3Ø - 3 Wire, 3Ø - 4 Wire Input

    • Current leakage / ground fault monitoring, 10mA - 30A

    • True RMS measurement

    • CBCT connection monitoring

    • Power ON delay, Trip time delay and Recovery time delay

    • Adjustable switching hysteresis

    • Two separate alarm relays with NO or NC operation selectable

    • Test and Reset buttons via front / remote

    • LCD with backlight

    • DIN Rail Mount

    • Size: 35mm (Width)

     DATA Sheet Link

    < Product photo may vary depending on part number selection.

     

    Analog / Digital Protection Relays

    Protection
    Altech is pleased to offer a variety of protection relays covering:

    • Phase Monitoring

    • Voltage Monitoring

    • Current Monitoring

    • Frequency Monitoring

    Current Leakage / Ground Fault Monitoring Protection relays help to maintain systems and ensure that proper action is taken when a fault is detected. Such functions help to preserve productivity and operational effectiveness of integral components. 

    Process Controllers - Supply Voltage
    230V AC
    Process Contollers - Input Voltage
    110/230 V AC (45-65Hz)
    Process Controllers - Input Measurement
    Current Leakage (Via CBCT)
    Process Controllers - Trip Setting
    Leakage Current: 10mA-30A / Pre-Alarm: 50-100% of Leakage Current Setting
    Process Controllers - Main Output
    SPDT -2 C/O - NO: 5A, 250 V AC and NC:3A, 250 V AC
    Process Controllers - Trip Time Settings
    Power ON Delay: 0.5-99.9 sec / Trip Time Delay: 0-99.9 sec / Recovery Time Delay: 0-99.9 sec / Response Time: greater than 30ms (if trip current 5x set value) / greater than 50ms (if trip current 1x set value)
    Process Controllers - Hysteresis
    5-40% of set value
    Process Controllers - Reset
    Auto/Manual (Selectable)
    Process Controllers - Power Consumption
    3VA max
    Process Controllers - Operating Temperature
    0 to 50°C (32 to 122°F)
    Process Controllers - Storage Temperature
    -20 to 75°C (-4 to 167°F)
    Process Controllers - Humidity (Non-Condensing)
    95% Relative Humidity
    Process Controllers - Weight
    217 grams(.48 lbs)
    Process Controllers - Display Type
    Liquid Crystal Display with backlight
    Process Controllers - Digits
    1 row of 3 digits
    Process Controllers - Resolution
    Current: 0.1mA / 1mA / 0.01A, 0.1A
    Process Controllers - Current Rating
    Measuring Range (RMS Value) 10mA - 30A, 45-65Hz
    Process Controllers - Latching
    Selectable
    Process Controllers - Electrical Connection
    1Ø-2 wire, 3Ø-3 wire, 3Ø- 4 wire
    Process Controllers - Current
    +/-5% of setting
    Process Controllers - Power Delay
    +/-5% of setting + 100ms
    Process Controllers - Protection Level
    IP50 (for faceplate), IP30 (for housing), IP20 (for terminals)