Safety Relays

Safety Relay OA 5642/43/44

Features

  • 2-4 output contacts
  • 8A Switching Current
  • International approvals:
    • TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
    • contact/coil ≥ 4 KV
    • contact/contact ≥ 4KV
  • High Creeping Distance:
    • contact/coil ≥ 5.5 mm
    • contact/contact ≥ 5.5 mm
  • Protection Rating IP 67, washable
  • Custom design available,
    • coil voltage 
    • coil resistance,
    • contact pressure
    • operate/release time
  • Compact size: 10.3mm high

Safety Relay OA/OW 5669

Features

  • 2 output contacts
  • 8A Switching Current
  • International approvals:
    TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
    contact/coil ≥ 4 KV
    contact/contact ≥ 4 KV
  • High Creeping Distance:
    contact/coil ≥ 8 mm
    contact/contact ≥ 5.5 mm
  • Protection Rating
  • OA Version: IP 40, flow solder proof
  • OW Version: IP 67, washable
  • Custom design available,
    • coil voltage 
    • coil resistance
    • contact pressure
    • operate/release time

Safety Relay OA/OW 5670

Features

  • Features 4 output contacts
  • 6A Switching Current
  • International approvals:
    TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
    contact/coil ≥ 4 KV
    contact/contact ≥ 3 KV
  • High Creeping Distance:
    contact/coil ≥ 8 mm
    contact/contact ≥ 4.5 mm
  • Protection Rating
    OA Version: IP 40, flow solder proof
    OW Version: IP 67, washable
  • Custom design available:
    • coil voltage
    • coil resistance,
    • contact pressure
    • operate/release time

Safety Relay OA 5621 / OA 5621S

Features

  • 4 output contacts
  • 8A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
    contact/coil ≥ 4 KV contact/contact ≥ 4 kV High
  • Creeping Distance:
    contact/coil ≥ 5.5 mm contact/contact ≥ 5.5 mm Protection Rating IP 67, washable
  • Custom design available:
    • coil voltage
    • coil resistance,
    • contact pressure
    • operate/release time
    • double gold contacts
  • S-Type: higher external clearance and creeping distance: contact/contact ≥ 7.5 mm

Safety Relay OA 5622 / OA 5622S

Features

  • 6 output contacts
  • 8A Switching Current
  • International approvals:
  • TÜV, UL, cUL Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
  • contact/coil ≥ 4 kV contact/contact ≥ 4 kV High Creeping Distance:
  • contact/coil ≥ 5.5 mm
  • contact/contact ≥ 5.5 mm
  • Protection Rating IP 67, washable
  • Custom design available,
    • coil voltage 
    • coil resistance
    • contact pressure 
    • operate/release time
    • double gold contacts
  • S-Type: higher external clearance and creeping distance: contact/contact ≥ 7.5 mm

Safety Relay OA 5667 / OA 5667S

Features

  • Features 6 output contacts
  • 8A Switching Current
  • International approvals:
  • TÜV, UL, cUL Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High breakdown Voltage:
  • contact/coil ≥ 4 kV contact/contact ≥ 4 kV High Creeping Distance:
    contact/coil ≥ 5.5 mm contact/contact ≥ 5.5 mm Protection Rating IP 67, washable.
  • Custom design available:
    • coil voltage
    • coil resistance
    • contact pressure
    • operate/release time
    • double gold contacts
  • S-Type: higher external clearance and creeping distance: contact/contact ≥ 7.5 mm

Safety Relay OA 5611

Features

  • Features 4 output contacts
  • 8A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials— mixed contact material optional
  • High coil voltage range
  • High switching voltage
  • High breakdown voltage:
    • contact/coil ≥ 4 KV
    • contact/contact ≥ 2.5
  • KV High creeping distance:
    • contact/coil ≥ 8 mm
    • contact/contact ≥ 4.5 mm Crown contacts
  • Solid connection between coil and contact housing
  • Compact size
  • Custom design available:
    • coil voltage
    • IP67 washable
    • contact pressure
    • coil resistance
    • operate/release time
    • low power dissipation
    • models

Safety Relay OA 5612

Features

  • 6 output contacts
  • 8A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact Gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • Very high switching voltage
  • High breakdown voltage: contact/coil ≥ 4 KV contact/contact ≥ 2.5 KV
  • High creeping distance: contact/coil ≥ 8 mm contact/contact ≥ 4.5 mm Crown contacts
  • Solid connection between coil and contact housing
  • Compact size
  • Custom design available:
    • coil voltage
    • IP67 washable
    • contact pressure
    • coil resistance
    • operate/release time
    • low power dissipation models

Safety Relay OA 5601

Features

  • 4 output contacts
  • 10A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High switching voltage
  • High breakdown voltage:
    • contact/coil ≥ 4 KV
    • contact/contact ≥ 4 KV
  • High creeping distance:
    • contact/coil ≥ 8 mm
    • contact/contact ≥ 5.5 mm
  • Crown contacts
  • Solid connection between coil and contact housing
  • Custom design available:
    • coil voltage
    • coil resistance
    • contact pressure
    • operate/release time

Safety Relay OA 5602

Features

  • 6 output contacts
  • 10A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High switching voltage
  • High breakdown voltage:
    • contact/coil ≥ 4 KV
    • contact/contact ≥ 4 KV
  • High creeping distance:
    • contact/coil ≥ 8 mm
    • contact/contact ≥ 5.5 mm
  • Crown contacts
  • Solid connection between coil and contact housing
  • Custom coil voltage available
  • Custom design available:
    • coil voltage
    • coil resistance
    • contact pressure
    • operate/release time

Safety Relay OA 5603

Features

  • 8 output contacts
  • 10A Switching Current
  • International approvals: TÜV, UL, cUL
  • Quality control check for each safety relay
  • Forced-guided contacts, all gold flash plated
  • Contact gap > 0.5 mm throughout life of relay
  • Various contact materials, mixed contact material optional
  • High coil voltage range
  • High switching voltage
  • High breakdown voltage:
    • contact/coil ≥ 4 KV
    • contact/contact ≥ 4 KV
  • High creeping distance:
    • contact/coil ≥ 8 mm
    • contact/contact ≥ 5.5 mm
  • Solid connection between coil and contact housing
  • Custom design available:
    • coil voltage
    • coil resistance
    • contact pressure
    • operate/release time

Accessories

Timers, Monitoring and Sensing Relays

Features

Compact Dold Relays with touch protected terminals snap on to standard DIN rail or can be panel mounted. Available in a variety of designs for industrial applications.

    • On/Off Delay Timers
    • Asymmetry Relays
    • Voltage/Current Sensing Relays
    • Motor Protection Relays
    • Multifunction Relays
    • Frequency Monitoring Relays
Product added to wishlist
Product added to compare.

This site uses Cookies.