Circuit Breakers
Filters
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
1C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
3C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C16UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
1C16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B16UR - UL1077 Recognized Supplementary Protector
1B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B16UR - UL1077 Recognized Supplementary Protector
2B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B16UR - UL1077 Recognized Supplementary Protector
3B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C16UR - UL1077 Recognized Supplementary Protector
1C16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2C16UR - UL1077 Recognized Supplementary Protector
2C16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C16UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C16UL - UL489 Miniature Molded Case Circuit Breaker
3C16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D03UL - UL489 Miniature Molded Case Circuit Breaker
1D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D16UL - UL489 Miniature Molded Case Circuit Breaker
1D16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D03UL - UL489 Miniature Molded Case Circuit Breaker
2D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D1UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D1UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C16UR - UL1077 Recognized Supplementary Protector
3C16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1D16UR - UL1077 Recognized Supplementary Protector
1D16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2D16UR - UL1077 Recognized Supplementary Protector
2D16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D16UL - UL489 Miniature Molded Case Circuit Breaker
2D16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D03UL - UL489 Miniature Molded Case Circuit Breaker
3D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D16UL - UL489 Miniature Molded Case Circuit Breaker
3D16UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D16UR - UL1077 Recognized Supplementary Protector
3D16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval


.png)