Circuit Breakers
Filters
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
1C1.6UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1B1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C1.6UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C1.6UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D1.6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D1.6UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D2.5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C1.6UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
3C1.6UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D1.6UL - UL489 Miniature Molded Case Circuit Breaker
1D1.6UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D1.6UL - UL489 Miniature Molded Case Circuit Breaker
2D1.6UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval


.png)