Circuit Breakers
Filters
Filter by:
Breaker Poles
Breaker Poles
Electrical Current Type
Electrical Current Type
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic - B-Trip - E-Trip
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
Filter by:
Breaker Poles
Breaker Poles
Electrical Current Type
Electrical Current Type
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic - B-Trip - E-Trip
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
1B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1B5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B05UR - UL1077 Recognized Supplementary Protector
2B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1B5UR - UL1077 Recognized Supplementary Protector
1B5UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B16UR - UL1077 Recognized Supplementary Protector
1B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2B5UR - UL1077 Recognized Supplementary Protector
2B5UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2B16UR - UL1077 Recognized Supplementary Protector
2B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B05UR - UL1077 Recognized Supplementary Protector
3B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B5UR - UL1077 Recognized Supplementary Protector
3B5UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B16UR - UL1077 Recognized Supplementary Protector
3B16UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E5UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E16UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
Filter by:
Breaker Poles
Breaker Poles
Electrical Current Type
Electrical Current Type
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic - B-Trip - E-Trip
Trip Charateristic
UL Breaker Approval
UL Breaker Approval


.png)


.png)














