Circuit Breakers
Filters
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
1C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
3C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C20UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
1C20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1B20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B20UR - UL1077 Recognized Supplementary Protector
1B20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B20UR - UL1077 Recognized Supplementary Protector
2B20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B20UR - UL1077 Recognized Supplementary Protector
3B20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C20UR - UL1077 Recognized Supplementary Protector
1C20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2C20UR - UL1077 Recognized Supplementary Protector
2C20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C20UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C20UL - UL489 Miniature Molded Case Circuit Breaker
3C20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D03UL - UL489 Miniature Molded Case Circuit Breaker
1D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D20UL - UL489 Miniature Molded Case Circuit Breaker
1D20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D03UL - UL489 Miniature Molded Case Circuit Breaker
2D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D1UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D1UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C20UR - UL1077 Recognized Supplementary Protector
3C20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1D20UR - UL1077 Recognized Supplementary Protector
1D20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2D20UR - UL1077 Recognized Supplementary Protector
2D20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D20UL - UL489 Miniature Molded Case Circuit Breaker
2D20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D03UL - UL489 Miniature Molded Case Circuit Breaker
3D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D20UL - UL489 Miniature Molded Case Circuit Breaker
3D20UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2E20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D20UR - UL1077 Recognized Supplementary Protector
3D20UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z20UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval


.png)


.png)