Circuit Breakers
Filters
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval
1C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C05UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
1C05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3C03UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
3C03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2C05UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1B05UR - UL1077 Recognized Supplementary Protector
1B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C13UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
1C13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1B13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1B13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2B13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2B05UR - UL1077 Recognized Supplementary Protector
2B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3B13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1B13UR - UL1077 Recognized Supplementary Protector
1B13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2C13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3B05UR - UL1077 Recognized Supplementary Protector
3B05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3B13UR - UL1077 Recognized Supplementary Protector
3B13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1C05UR - UL1077 Recognized Supplementary Protector
1C05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1C13UR - UL1077 Recognized Supplementary Protector
1C13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2C05UR - UL1077 Recognized Supplementary Protector
2C05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2C13UR - UL1077 Recognized Supplementary Protector
2C13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3C13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3C13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1D13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1D13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2C13UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
2C13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3C05UL - DLS9 - UL489 Miniature Molded Case Circuit Breaker
3C05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1C075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1C075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C13UL - UL489 Miniature Molded Case Circuit Breaker
3C13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D03UL - UL489 Miniature Molded Case Circuit Breaker
1D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D05UL - UL489 Miniature Molded Case Circuit Breaker
1D05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
1D13UL - UL489 Miniature Molded Case Circuit Breaker
1D13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D03UL - UL489 Miniature Molded Case Circuit Breaker
2D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D05UL - UL489 Miniature Molded Case Circuit Breaker
2D05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D1UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D1UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3C05UR - UL1077 Recognized Supplementary Protector
3C05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2D13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2D13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2D13UL - UL489 Miniature Molded Case Circuit Breaker
2D13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3C13UR - UL1077 Recognized Supplementary Protector
3C13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1D05UR - UL1077 Recognized Supplementary Protector
1D05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
1D13UR - UL1077 Recognized Supplementary Protector
1D13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2D05UR - UL1077 Recognized Supplementary Protector
2D05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
2D13UR - UL1077 Recognized Supplementary Protector
2D13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3D05UR - UL1077 Recognized Supplementary Protector
3D05UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3D05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3D13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1E13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1E13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D03UL - UL489 Miniature Molded Case Circuit Breaker
3D03UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D05UL - UL489 Miniature Molded Case Circuit Breaker
3D05UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
3D13UL - UL489 Miniature Molded Case Circuit Breaker
3D13UL
AC (UL Series) and DC (DL Series) DIN Rail Mounted 17.5mm width Thermal Magnetic 240V, 480Y/277V AC, 50/60Hz 125V DC (1 pole); 125/250V DC (2 pole) 10kA Short Circuit Interrupting Capacity HACR Type 40°C Line/Load reversibleDATA SHEET < Product photo imprint will vary depending on part number selection.
2E13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2E13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3E13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3E13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1G13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1G13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2G13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2G13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3G13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3G13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
1Z13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
1Z13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
2Z13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
2Z13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3D13UR - UL1077 Recognized Supplementary Protector
3D13UR
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short CircuitWithstand Capacity Applications (on the load side of Branch Circuit Protection) include:Sensitive Electronics, Power Supplies, Appliance circuits, etc.DATA SHEET < Product photo imprint will vary depending on part number selection.
3Z03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z03UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z05UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z075UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
3Z13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect”
3Z13UM
DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps...
Filter by:
Breaker Poles
Breaker Poles
Rated Voltage - Breakers
Rated Voltage - Breakers
Trip Charateristic
Trip Charateristic
UL Breaker Approval
UL Breaker Approval


.png)