Circuit Breakers 3D60UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 3D60UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 3D63UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 3D63UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E03UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E03UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E05UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E05UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E075UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E075UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E1UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E1UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E2UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E2UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E2.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E2.5UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E3UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E3UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E3.5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E3.5UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E4UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E4UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E5UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E5UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E6UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E6UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E8UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E8UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E10UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E10UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E12UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E12UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E13UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E13UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E15UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E15UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E16UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E16UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E20UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E20UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E25UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E25UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E30UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E30UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E32UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E32UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View
Circuit Breakers 1E40UM - DLS8 - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” 1E40UM DIN Rail Mounted 17.5mm width per pole Thermal Magnetic 0.3-60A / 480Y/277V AC, 50/60Hz Also DC rated 480Y/277V AC0.3-25A: 1 pole - 42V DC; 2 Pole - 80V DC30-60A: 1 pole - 24V DC; 2 Pole - 60V DC 10kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line, AC General Use,AC Resistance, AC Discharge Lamps... View