Extended / Direct Handle Motor Disconnect Switch
The KU/VKA...N series can be used with extended and direct handles.
- 3-4 poles
- General Purpose Current: 25A - 150A
- Maximum Voltage: 600V AC
- Motor FLA @ 480V AC: 17.5A - 34A
- Motor FLA @ 600V AC: 11A - 83A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG - 4-1/0AWG
|
|
|
Extended Handle Accessories
- Door Interlock Handles
- Door Interlock Shaft
- Auxiliary Switches
- Fuse Holder
- Direct Handles
- Door Mountng Kits
DRILL TEMPLATES:
LK10
LK11
OKA 0V LK2
OKA KU LK10
- Mounting Alternatives - Aluminum DIN Rail
|
|
|
Extended / Direct Handle Motor Disconnect Switch
The KUE series only requires an additional cover plate (see below) which makes the switch IP20 touch proof.
- 3 poles
- General Purpose Current: 25A - 60A
- Maximum Voltage: 600V AC
- Motor FLA @ 480V AC: 17.5A - 34A
- Motor FLA @ 600V AC: 11A - 27A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG - 12-4AWG
Suitable Accessories
|
|
|
Extended / Direct Handle Motor Disconnect Switch
The EVA series includes a cover plate.
- 3 poles
- General Purpose Current: 80A - 150A
- Maximum Voltage: 600V AC
- Motor FLA @ 600V AC: 47A - 83A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 4-1/0AWG
|
|
|
Enclosed Motor Disconnect Switch
These enclosed switches can be used locally at the motor.
- 3-4 poles
- General Purpose Current: 25A - 150A
- Maximum Voltage: 600V AC
- Motor FLA @ 480V AC: 17.5A - 34A
- Motor FLA @ 600V AC: 11A - 83A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG - 4-1/0AWG
- Environmental Rating: NEMA Type 4X
|
|
|
Fused - Enclosed Motor Disconnect Switch
These enclosed switches can be used locally at the motor.
- 3 pole
- General Purpose Current: 30A
- Maximum Voltage: 600V AC
- Motor FLA @ 600V AC: 54A - 83A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG
- Environmental Rating: NEMA Type 4X
|
|
|
Stainless Steel Enclosed Motor Disconnect Switch
These enclosures are ideal where chemicals are used for cleaning and maintenance such as food processing plants and breweries. Mining is another application area. Their stainless steel construction is extremely resistant to corrosion, and the enclosure is also rated to IP66.
- 3-4 poles
- General Purpose Current: 25A - 125A
- Maximum Voltage: 600V AC
- Motor FLA @ 480V AC: 17.5A - 34A
- Motor FLA @ 600V AC: 11A - 68A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG
- Environmental Rating: NEMA Type 4X
|
|
|